ggft5fdhf4
Products / Services
JGT Haemodynamics offers high quality B. Braun products and services for diagnostic and interventional cardiology procedures.
Angiography
Angiography is the study of the arterial blood vessels by injection of contrast media through a catheter (thin flexible tube).
Angiography catheters
Angiodyn diagnostic catheters for coronary angiographies
Description
Superior flow rates thanks to extra large inner catheter lumen
Symmetrically braided shaft for 1:1 force transmission
Atraumatic non braided tip
Color coded ergonomic catheter hub
Product Range
4 French – selective, flush and multipack configurations
5 French – selective, flush and multipack configurations
6 French – selective, flush and multipack configurations
Manifolds
Angiodyn manifolds help you managing your procedure
Description
Customized fluid flow control without disconnecting existing lines for connecting new fluid lines.
Connections to
catheter
saline solution bag
contrast medium
monitoring systems
The Angiodyn manifold product range
2-port or 3-port manifolds or single stopcocks
full- and half-body design
On or Off version
pressure resistance 35bar (500 psi) grey handles
pressure resistance 70bar (1000 psi) yellow handles
rotating adaptors where the customer needs them
Advantages
smooth turning handles (ergonomic design)
transparent housing for visual control
Luer lock fitting male/female
colour coded handles (full-body version)
Guide wires
Angiodyn guide wires for introduction, stabilization and positioning of angiographic catheters
Description
Standard version with dispenser and Luer lock - fitting for flushing the wire
Wide range of guide wires with J-tip or straight end
Different diameters
Lengths: 150 cm, 175 cm, 200 cm, 260 cm
High quality PTFE-coated stainless nickel-chromium steel (C)
Advantages
Highly flexible and smoothly rounded wire tip
Excellent steerability and stability
Various tip configurations:
J-tip, fixed core or movable core.
Straight tip, fixed core or movable core.
Finger-straightenable J-tip, fixed core or movable core.
Straightener for J-tip
High pressure tubing lines
Angiodyn high pressure tubing lines for angiographic interventions
Description
Material: braided PUR (very flexible)
Pressure stability tested up to 82 bar / 1200 psi.
Luer lock fitting male/female with rotating adaptor.
Single sterile tubing lines available in different lengths (50cm/75cm/100cm/120cm).
Material: PVC (flexible)
Pressure stability tested up to 70 bar / 1000 psi.
Single sterile tubing lines available in different lengths.
With rotating adaptor (50cm/75cm/100cm/120cm).
Advantages
Transparent for visual control
Tubing lengths for all needs
Luer lock fitting male/female
Angiographic syringes
Angiodyn angiographic syringes for manual contrast medium injection
Description
10 ml syringes with and withoutrotating adaptor
20 ml syringes with rotating adaptor
12 ml syringes with and without rotating adaptor
medium sized grip plate
security stop at 1.0 ml
with and without lateral finger rings
other volume syringes available as kit components
rubber gasket for smooth plunger action with double seal
crystal clear barrel
The Angiodyn injector syringes for powered contrast medium injection
developed for high pressure injectors up to 84 bar (1200 psi)
transparent, high quality polypropylene for easy identification of air bubbles
plunger with double seal prevents air aspiration and leakage
protective cap to avoid contamination when using aseptic technique
connection to all Luer standards possible
single sterile injector syringes available for Angiomat 6000 TM, Illumena and Medrad Mark V
Spectraline disposable syringes to connect with manifolds and catheters
for manual injection of contrast media, heparin, saline solution and other fluids
Accessories for angiography
Single sterile products for angiographic interventions
Description
Contrast medium saver systems
Contrast medium saver spike
Contrast medium saver tube
Monitoring procedure kits for invasive pressure measurement
Disposable pressure transducer Combitrans
Disposable domes for use with reusable pressure transducers
Complete systems for invasive pressure measurement
Intradyn – introducer for interventional cardiology
Arterial introducer using Seldinger technique according to Desilets-Hofmann
Image intensifier covers and bags
Protect your equipment from contamination and dust
PE transparent cover
With elastic or string fixation
Angioplasty
With its Solution Oriented Angioplasty concept, Vascular Systems offers a total line of highly effective and safe products to cover every individual patient need.
Coroflex® Blue Ultra
Coronary Cobalt-Chromium bare metal stent with ultra thin strut thickness performs better
Description
Coroflex® Blue Ultra is the only stent especially designed for small vessels and most challenging cases requiring PTCA balloon like handling. The strut thickness impacts on the crossing profile and system flexibility significantly , i. e. the thinner the struts the smaller the crossing profile and the higher the flexibility.
The Coroflex® Blue Ultra with only 50 µm strut thickness set the benchmark within the coronary stent field. Coroflex® Blue Ultra offers the best crossing performance combined with high technical success rates even in complex lesions.
Ultra thin stent struts for ultra large lumen gain:
50 µm thin stent struts ensure highest post procedural lumen profit for maximum blood flow.
Coroflex® Blue Ultra is your best choice for small vessel treatment even in most challenging lesions.
Advantages
The world first CoCr stent with 50 µm strut thickness
Lowest lesion entry profile (0.016”)
Lowest crossing profi
SeQuent® Please
Drug eluting balloon to treat vascular stenosis
Description
B. Braun Vascular Systems presents a Drug Eluting Balloon for PTCA, based on a polymer-free carrier matrix. This most innovative product is the result of our sustained research for new options and improvements in the field of coronary angioplasty. Clinically proven, it offers completely new procedural options to treat vascular stenoses since the drug elution does not require a stent platform.
Coroflex® Please
Superior flexibility and proven drug release
Description
Coroflex® Please is the recent evolution of our coronary stent family and especially addressed to the still existing challenges in the era of drug releasing stents.
Following actual clinical requirements, Coroflex® Please combines our know-how of state-of-the-art stent systems with a clinically proven and effective drug.
As a successful combination of clinical input, science and engineering, Coroflex® Please is designed to overcome current procedural limitations of today´s first generation DES.
The reliable drug Paclitaxel, the optimized DES coating technology and the outstanding Coroflex® stent platform offer numerous advantages to the user.
Advantages
Paclitaxel – Effective anti-proliferative drug
Numerous studies demonstrated the positive effects of Paclitaxel on inhibiting Smooth Muscle Cell (SMC) proliferation and migration.
Paclitaxel supports an uniform drug distribution and suppresses the formation of neointimal hyperplasia due to its lipophilic property.
Coroflex® Platform – Highly flexible coronary stent systems
Coroflex® Please offers excellent mechanical properties and a high system flexibility designed for optimal stent deliverability and deployment.
The excellent flexibility of the SeQuent® Catheter technology enables access to the most challenging lesions.
P-Matrix – Innovative coating technology
The state of the art coating technology assures a precise Paclitaxel load combined with an excellent surface integrity during stent implantation.
Best polymer thermostability ensures an accurate balloon deflation and system removal after stent expansion.
SeQuent® II
Rapid Exchange PTCA Balloon Catheter
Description
SeQuent® II offers an improved sequential tip design (USP) and numerous other features for enhanced crossability, flexibility and pressure resistance. Especially the balloon sizes Ø 1.25 and 1.5 mm with their practically non compliant, high pressure balloon performance will offer the physicians more treatment options in challenging CTO patients
Advantages
State of the art crossability
Extremely downsized 0.016“ tip
Reduced balloon profile 0.024’’-0.028”
Improved taper geometry
Optimized sequential tip proportions
Elongated highly flexible zone for guidewire trackability´and lesion crossing
Shortened and further downsized robust tip for calcified lesions and recrossing
Best torque & push
Innovation awarded shaft material with highest available kink resistance
Enhanced balloon flexibility
Upgraded balloon folding and profile
True 6 F “kissing” balloon capability
Re-designed guide wire exit